| 1 |
burst position of rod#1, charged at 520°C with prior internal pressure 50 bar |
| 2 |
burst position of rod#2 charged at 520°C with prior internal pressure 35 bar |
| 3 |
burst position of rod #3, charged at 520°C with prior internal pressure 55 bar |
| 4 |
burst position of rod#4, charged at 520°C with prior internal pressure 50 bar |
| 5 |
burst postion of rod#5, charged at 520°C with prior internal pressure 40 bar |
| 6 |
burst postion of rod#6, charged at 520°C with prior internal pressure 35 bar |
| 7 |
burst postion of rod#7, charged at 520°C with prior internal pressure 55 bar |
| 8 |
burst postion of rod#8, charged at 520°C with prior internal pressure 50 bar |
| 9 |
burst postion of rod#9, charged at 520°C with prior internal pressure 40 bar |
| 10 |
burst postion of rod#10, charged at 470°C with prior internal pressure 45 bar |
| 11 |
burst postion of rod#11, charged at 480°C with prior internal pressure 40 bar |
| 12 |
burst postion of rod#12, charged at 480°C with prior internal pressure 50 bar |
| 13 |
burst postion of rod#13, charged at 480°C with prior internal pressure 50 bar |
| 14 |
burst postion of rod#14, charged at 480°C with prior internal pressure 50 bar |
| 16 |
burst postion of rod#16, charged at 520°C with prior internal pressure 45 bar |
| 17 |
burst postion of rod#17, charged at 520°C with prior internal pressure 40 bar |
| 18 |
burst postion of rod#18, charged at 520°C with prior internal pressure 50 bar |
| 19 |
burst postion of rod#19, charged at 520°C with prior internal pressure 50 bar |
| 20 |
burst postion of rod#20, charged at 520°C with prior internal pressure 50 bar |
| 21 |
burst postion of rod#21, charged at 520°C with prior internal pressure 45 bar |